久久精亚洲国产一区二区_亚洲日韩一级在线毛_手机精品福利在线观看_潘甜甜手机的密码在线查看_中文字幕——97超碰网_亚洲中文无码日韩一区_青青久精品观看视频最新_日韩亚洲制服欧美综合_午夜毛片在线影院_這裏隻有国产强伦姧在线观看

Your location:Home page > Product > Municipal plumbing
Municipal plumbing

PVC-U water supply pipeline

Add time:2021-08-13 16:34:16   Number of views:637  

Category:Municipal plumbing

Introduction:

The PVC-U water supply pipes produced by our company are defined as Unplasticized Polyvinly Chloride in the ISO standard. Only necessary additives are allowed, no plasticizers, hence the name. PVC-U pipes for water supply use PVC resin as the main raw material, add appropriate amount of additives, and are processed and formed by mixing, extruding, sizing, cooling, cutting and expanding. The injection-molded pipe fittings are made of PVC resin as the main raw material, add appropriate amount of additives, and are uniformly mixed and then injection-molded. The products have been tested by authoritative departments such as the National Plastic Products Quality Supervision and Inspection Center, the National Building Materials Testing Center, and the Hebei Provincial Health and Epidemic Prevention Station, and fully meet the requirements of relevant national standards and enterprise standard...

The PVC-U water supply pipes produced by our company are defined as Unplasticized Polyvinly Chloride in the ISO standard. Only necessary additives are allowed, no plasticizers, hence the name. PVC-U pipes for water supply use PVC resin as the main raw material, add appropriate amount of additives, and are processed and formed by mixing, extruding, sizing, cooling, cutting and expanding. The injection-molded pipe fittings are made of PVC resin as the main raw material, add appropriate amount of additives, and are uniformly mixed and then injection-molded. The products have been tested by authoritative departments such as the National Plastic Products Quality Supervision and Inspection Center, the National Building Materials Testing Center, and the Hebei Provincial Health and Epidemic Prevention Station, and fully meet the requirements of relevant national standards and enterprise standards. Executive standard: GB/T10002.1-2006; GB/T10002.2-2003;

Product Features:

1. Hygiene
The green lead-free stabilization system is adopted, which is hygienic and non-toxic, does not scale or breed microorganisms such as algae during use, and the water quality is not subject to secondary pollution.

2. Light weight
The weight per unit length is 1/5 of the cast iron pipe and 1/4 of the ductile iron pipe, which is convenient for installation and transportation.

3. Easy to install
Adopt glue connection and rubber sealing ring connection, easy installation and reliable sealing.

4. Low cost
The transportation, installation and material costs are low, and the total construction cost of the project is 30-40% lower than that of cast iron pipes, which is also much lower than that of similar plastic pipes.

5. Long life
Under normal working pressure, the service life can reach more than 50 years.

6. High strength
The tensile strength at room temperature is not less than 45MPa.

7. Low resistance
The inner wall is smooth, the fluid medium resistance is small, no blockage, and the head loss is more than 25% lower than that of cast iron pipes.

8. Corrosion resistance
It has good acid resistance, alkali resistance and corrosion resistance, and there will be no pitting corrosion during use.

9, heat insulation, flame retardant
The thermal conductivity of PVC-U pipe is lower than that of traditional pipe, and it is self-extinguishing and difficult to burn.

Nominal pressure grade and size of pipe: Unit: mm

Nominal diameter
dnmm

0.63MPa

0.8MPa

1.0MPa

1.25MPa

1.6MPa

2.5MPa

Wall thickness

Tolerance

Wall thickness

Tolerance

Wall thickness

Tolerance

Wall thickness

Tolerance

Wall thickness

Tolerance

Wall thickness

Tolerance

20

 

 

 

 

 

 

 

 

 

 

2.3

+0.6
0

25

 

 

 

 

 

 

 

 

2.0

+0.4
0

2.8

+0,5
0

32

 

 

 

 

 

 

2.0

+0.4
0

2.4

+0.5
0

3,6

+0.6
0

40

 

 

 

 

2.0

+0.4
0

2.4

+0.5
0

3.0

+0,5
0

4.5

+0,7
0

50

 

 

2.0

+0.4
0

2.4

+0.5
0

3.0

+0.5
0

3.7

+0.6
0

5.6

+0.9
0

63

2.0

+0.4
0

2.5

+0.5
0

3.0

+0.5
0

3.8

+0.6
0

4.7

+0.8
0

7.1

+1.1
0

75

2.3

+0.5
0

2.9

+0.5
0

3.6

+0.6
0

4.5

+0.7
0

5.6

+0.9
0

8.4

+1.3
0

90

2.8

+0.5
0

3.5

+0.6
0

4.3

+0.7
0

5.4

+0.9
0

6.7

+1.1
0

10.1

+1.6
0

110

2.7

+0,5
0

3.4

+0.6
0

4.2

+0.7
0

5,3

+0.8
0

6.6

+1.0
0

10.0

+1.5
0

125

3.1

+0.6
0

3.9

+0.6
0

4.8

+0.8
0

6.0

+0.9
0

7.4

+1,2
0

11.4

+1.8
0

140

3.5

+0.6
0

4.3

+0.7
0

5.4

+0.9
0

6.7

+1.1
0

8.3

+1.3
0

12.7

+2.0
0

160

4,0

+0.6
0

4.9

+0.8
0

6.2

+1.0
0

7.7

+1.2
0

9.5

+1.5
0

14.6

+2.2
0

180

4.4

+0.7
0

5.5

+0.9
0

6.9

+1.1
0

8.6

+1.3
0

10.7

+1.7
0

16.4

+2.5
0

200

4.9

+0.8
0

6.2

+1.0
0

7.7

+1.2
0

9.6

+1.5
0

11.9

+1.8
0

18.2

+2.8
0

225

5.5

+0.9
0

6.9

+1.1
0

8.6

+1.3
0

10.8

+1.7
0

13.4

+2.1
0

 

 

250

6.2

+1.0
0

7.7

+1.2
0

9.6

+1.5
0

11.9

+1.8
0

14.8

+2.3
0

 

 

280

6.9

+1.1
0

8.6

+1.3
0

10.7

+1.7
0

13.4

+2.1
0

16.6

+2.5
0

 

 

315

7.7

+1.2
0

9.7

+1.5
0

12.1

+1.9
0

15.0

+2.3
0

18.7

+2.9
0

 

 

355

8.7

+1.4
0

10.9

+1.7
0

13.6

+2.1
0

16.9

+2.6
0

21.1

+3.2
0

 

 

400

9.8

+1,5
0

12.3

+1.9
0

15.3

+2.3
0

19.1

+2.9
0

23.7

+3.6
0

 

 

450

11.0

+1.7
0

13.8

+2.1
0

17.2

+2.6
0

21,5

+3.3
0

26.7

+4.1
0

 

 

500

12.3

+1.9
0

15.3

+2.3
0

19.1

+2.9
0

23.9

+3.6
0

29.7

+4.5
0

 

 

560

13.7

+2.1
0

17.2

+2.6
0

21.4

+3.3
0

26.7

+4.1
0

 

 

 

 

630

15.4

+2.4
0

19.3

+2.9
0

24.1

+3.7
0

30.0

+4.5
0

 

 

 

 

710

17.4

+2.7
0

21.8

+3.3
0

27.2

+4.1
0

 

 

 

 

 

 

800

19.6

+3.0
0

24.5

+3.7
0

30.6

+4.6
0

 

 

 

 

 

 

900

22.0

+3.4
0

27.6

+4.2
0

 

 

 

 

 

 

 

 

1000

24.5

+3.7
0

30.6

+46
0

 

 

 

 

 

 

 

 

1. Appearance
The inner and outer surfaces of the pipe should be smooth, without obvious scratches, dents, visible impurities and other surface defects that affect the performance of the pipe. The end face of the pipe should be cut flat and perpendicular to the axis.

2. Opaqueness
The tubing should be opaque.

3. Length
The overall length of the pipe is generally 4 meters, 5 meters, and 6 meters, which can also be determined through negotiation between the supply and demand sides.

4. Color
PVC-U water supply pipes are generally gray, and other colors can also be produced through negotiation between the supplier and the buyer.

5. Physical and mechanical properties

Project

Technical index

Test method

Softening temperature of micro-card

≥ 80 ℃

According to "GB/T10002.1-2006" standard

Longitudinal retraction rate

≤ 5%

Dichloromethane impregnation experiment

At 15 ℃ and 15min, the surface change should not be inferior to that of 4N

Drop hammer impact test (0 ℃) TIR

≤ 5%

Hydraulic test

No rupture, no leakage

Connection sealing test

No rupture, no leakage


6. Hygienic performance
The hygienic performance of pipes and fittings complies with the Health and Safety Evaluation Specifications for Drinking Water Transmission and Distribution Equipment and Protective Materials of the Ministry of Health.

PVC-U injection molding pipe fittings for water supply

1. Color
It is generally gray, and other colors can also be produced through negotiation between the supplier and the buyer.

2. Appearance
The surface of the pipe fittings should be smooth, and no defects such as cracks, bubbles, peeling, severe cold spots, obvious impurities, uneven color, decomposition and discoloration are allowed.

3. Physical and mechanical properties

 

Project

 

Require

Microcard softening temperature

≥74℃

Oven experiment

Comply with GB/T8803-2001

Drop test

No rupture

Hydraulic test

Nominal outer diameter/dn

Test temperature/℃

Test pressure/MPa

Experiment time/h

Experimental requirements

dn≤90mm

20

4.2×PN

1

No rupture
No leakage

3.2×PN

1000

dn>90mm

20

3.36×PN

1

2.56×PN

1000

Auxiliary accessories
Physical properties of rubber seal

Project

Indicators

Note

Shore hardness

45-55degree

Health indicator complianceGB/T17219

Elongation

≥500%

Tensile strength

≥16MPa

Deformation

≤20%

Aging factor

≥0.8(70°,144h)

2. Performance index of adhesive

Project

Indicators

Requirements

Viscosity

100-110 centipoise

Hygienic indexes conform to GB/T17219, and the shear strength of bonded places is ≥ 5 MPa

Chroma

< 1 °

Residual chlor-alkali content

< 0.7 mg/L

Volatile acids

< 0.005 mg/L

Solid content

11.9%-12%

Turbidity

< 0.5 °

Cyanide

Not to be detected

Potassium permanganate consumption

< 1mg/L

Taste

No peculiar smell

PVC-U water supply pipe installation procedure

R-R elastic sealing rubber ring connection installation procedure:

1. Wipe the inner surface of the socket groove and the outer surface of the socket with a veil;

2. Put the outskirts in the socket groove in the correct way (the big end is inward, the small end is outward);

3. Draw the insertion depth mark on the socket end;

4. Apply lubricant to the broker and the socket; (oil is prohibited)

5. Use the wire tensioner or the lever hoist to pull it in place at one time;

6. Use a feeler gauge to check whether the rubber ring is normal along the circumference.

T-S method pipeline connection steps:

1. Cutting - cut the pipe evenly and vertically according to the required size, and then chamfer;

2. Cleaning - clean the dust or grease on the surface of the socket and the inner surface of the socket;

3. Spreading - spread the adhesive evenly and quickly on the outer surface of the socket and the inner surface of the socket;

4. Insertion - Align the center line of the two pipes or pipes and fittings, insert them quickly and rotate 1/4 turn to make the adhesive evenly distribute the gap between the socket and the socket;

5. Keep - keep it still after the insertion is completed to allow the adhesive to solidify, keep it for at least one minute, and finally wipe off the excess adhesive outside the tube;

6. End - After the connection is completed, avoid applying load to the pipe for ten minutes.

PVC-U pipes can be widely used in water transmission and distribution projects where the water temperature is not higher than 45 °C, and are widely used in the following fields:

>>Urban Water Supply Project

>>Agricultural water-saving irrigation, low-pressure irrigation projects

>>Water supply project in water source

>>Industrial production pipe network

>>mine

>>Residential quarters, residential upstairs water projects

 

Copyright ? Hebei Lile Pipe Co., Ltd. http://chdnet.cn/ All Rights Reserved    Website productionSanjin Technology     
HomeTelProduct